Category: Uncategorised
| TEV500 | |||
| Input Voltage | Max 130V (Single Phase) 50/60Hz | ||
| CP Simulation | States A, B, C, D | ||
| Error Simulation | CP error “E”, PE (Earth Fault) Error | ||
| CCID TRIP simulation | Yes (>25mA @130V) | ||
| Test Connector Type |
IEC62196-2 Type 1 male (Male to Female Adaptor Included/Tesla) |
||
| Measurement Category | CAT II 300V | ||
| PE Pre-Test: | Yes | ||
| Test Cable Length | 9.8” (25 cm) | ||
| Power | Powered by Charging System | ||
| Dimensions | 6.9 x 4.2 x 2.8'' (175.3 x 106.7 x 71.1mm) | ||
| Weight | 1.2lbs (544.3g) | ||
| Control Pilot (CP)State (Vehicle Simulation) | |||
| Vehicle State | State Description | CP/PE Resistance | Vehicle State |
| A | Electric vehicle not connected | open (∞) | ±12V @ 1KHz |
| B | Electric vehicle connected, not ready to charge | 2.74 K | +9V/-12V@1KHz |
| C |
Electric vehicle connected, ready to charge, ventilation not required |
882Ω | +6V/-12 @ 1KHz |
| D |
Electric vehicle connected, ready to charge, ventillation required |
246Ω | +6V/-12 @ 1KHz |
| TEV500 | |||
| Input voltage | UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal | ||
| EV connector (EVC-13) |
SAE J1772 (Type 1, 5P single phase) for measuring purpose Adapter SAEJ1772 to NACS for measurement purpose |
||
| Internal power consumption | <1W | ||
| Operating temperature | -20 to 40 degree C (-4 to 104F) | ||
| Storage temperature | -20 to 40 degree C (-4 to 104F) | ||
| Operating Altitude | 2000 mtr (6562ft) | ||
| Weight | 641.5G (1.4lbs) | ||
| Safety standards | IEC 61010-1, Pollution Degree 2 | ||
| Measurement category | CAT II 300V | ||
| IP protection class | IP40 | ||
| Functions | |||
| Indication LEDs | L1, PE error | ||
| CP States | A, B, C , D | ||
| CP Error “E” | On / Off | ||
| PE Error | On / Off | ||
| GFCI Test | YES, test resitor connected between L1 and PE | ||
| PE Pre-Test (typical) | YES | ||
| Outputs (for test purpose only) | |||
| Measuring terminals | Max. 250 V 50/60 Hz, CAT II 300 V | ||
| L1, L2/N, PE | |||
| CP signal output terminals | Approx. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE |