OxyTechw2 GAL Dissolved Oxygen Sensor


Quantity: Out Of Stock

Category: WaterWatch2 Monitors

Quick Overview:

Galvanic Dissolved Oxygen Sensor


Physical
Dimensions (hxwxd) Ø58mm, 88 mm long
Weight 0.5 kg
Protection Class IP68
Enclosure Material Polyoxymethylene (POM) with HDPE membrane
Cable Entry Integral Cable Gland
Cable Length 10 metres standard, 100 metres maximum
Interface to Monitor  
Power Supply 12 VDC from Monitor
Sensor Output ModTechw², RS485
Environmental Data  
Operating/Storage Temperature 0 to 50ºC
Location Indoor/Outdoor
Pressure Rating 5 Bar
Maintenance  
Service No routine service

Periodic cleaning is required at a frequncy determined by the application. Our self cleaning shaft option is highly recommended, this eliminates manual cleaning between calibrations.
Calibration The sensor is inherently stable, calibration should be carried out to suit the application. Our recommendation is every 6 months.
Measurement Characteristics
Principal of Operation Galvanic Oxygen Partial Pressure Cell, Self Polarising, Self Temperature Compensating

Iron/Silver Electrode Combination
Temperature NTC
Accuracy +/- 0.1 mg/l or +/- 1%Sat
Repeatability Better than +/- 1% FSD
Display Resolution see 7300w² Monitor
Response Time 90% of step change in less than 90 seconds
Flowrate 1 cm/second
Units mg/l, ppm, %Sat
Range 0-20 mg/l (ppm)
0-200 %Sat

Tag: #224006  #224007  #224529  #224531  #224533 

Share: Messenger


Galvanic Dissolved Oxygen Sensor


Physical
Dimensions (hxwxd) Ø58mm, 88 mm long
Weight 0.5 kg
Protection Class IP68
Enclosure Material Polyoxymethylene (POM) with HDPE membrane
Cable Entry Integral Cable Gland
Cable Length 10 metres standard, 100 metres maximum
Interface to Monitor  
Power Supply 12 VDC from Monitor
Sensor Output ModTechw², RS485
Environmental Data  
Operating/Storage Temperature 0 to 50ºC
Location Indoor/Outdoor
Pressure Rating 5 Bar
Maintenance  
Service No routine service

Periodic cleaning is required at a frequncy determined by the application. Our self cleaning shaft option is highly recommended, this eliminates manual cleaning between calibrations.
Calibration The sensor is inherently stable, calibration should be carried out to suit the application. Our recommendation is every 6 months.
Measurement Characteristics
Principal of Operation Galvanic Oxygen Partial Pressure Cell, Self Polarising, Self Temperature Compensating

Iron/Silver Electrode Combination
Temperature NTC
Accuracy +/- 0.1 mg/l or +/- 1%Sat
Repeatability Better than +/- 1% FSD
Display Resolution see 7300w² Monitor
Response Time 90% of step change in less than 90 seconds
Flowrate 1 cm/second
Units mg/l, ppm, %Sat
Range 0-20 mg/l (ppm)
0-200 %Sat


Sorry, Currently No Video Uploaded.

OxyTechw2 GAL Dissolved Oxygen Sensor


Please Leave Your Product Enquiry Here. We will Get Back To You Soon.

Product Specifications

  • Product SKU : -
  • Weight (GRAM) : -
  • Dimension : -