Orion STAR A215 Advanced pH/Conductivity Benchtop Multiparameter Meter


Quantity: Out Of Stock

Category: Star A Series Benchtop Meters

Quick Overview:

Record accurate and reliable pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature measurements with the Thermo Scientific™ Orion™ Star A215 pH and Conductivity Benchtop Meter, ideal for a wide range of applications and advanced pH and conductivity analysis in the lab. Use the two meter channels to measure pH and conductivity simultaneously or view each channel separately. Perform up to a 5 point calibration, log up to 2000 data point sets with time / date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer.

Options:

STARA2150: Orion Star A215 pH/conductivity benchtop meter, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate

STARA2155: Orion Star A215 pH/conductivity benchtop meter kit with 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD DuraProbe 4-cell conductivity sensor, 011007 Orion 1413 μS conductivity standard, ROSS pH buffer & solutions kit, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Tag: #STARA2150  #STARA2155 

Share: Messenger


Description Orion Star A215 pH/conductivity benchtop meter with stand
Item Description Orion Star A215 pH/conductivity benchtop meter with stand
Includes Star A215 pH/conductivity meter, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Range (pH) -2.000 to 20.000pH
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Range (mV) ±2000.0mV
Range (Relative mV) ±2000.0mV
Range (ORP) ±2000.0mV
Resolution (mV) 0.1mV
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Isopotential Point 7.000pH
Range (Conductivity) 0.001 µS/cm to 3000 mS/cm
Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS) 0.001 to 200.0 ppm
Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
Accuracy (TDS) 0.5% of reading ±1 digit
TDS Factor Range Linear (0.02 to 9.99)
Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
Accuracy (Salinity) 0.5% of reading ±1 digit
Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
Range (Resistivity) 2 ohm to 100.0 meg-ohm
Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
Accuracy (Resistivity) 0.5% of reading ±1 digit
Cell Constant 0.001 to 199.9cm-1
Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (Metric) Reference 5, 10, 15, 20, 25°C
Calibration pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option and temperature
Calibration Points (pH) 1 to 5
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity) Up to 5
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 2
Display Type Graphic LCD with backlight
Backlight Option Yes, selectable
Keypad Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes pH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output High/low limit alarm, calibration due alarm
Methods 10 per channel with password protection
Languages English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
Inputs BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
Outputs USB, RS232
Power Supply Universal AC adapter (included) or 4 AA batteries (sold separately)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Battery Type Four AA (sold separately)
Battery Life 800 hours
IP Rating IP-54
Certifications/Compliance CE, TUV 3-1, FCC Class A
Temperature (English) Operating 41° to 113°F (ambient)
Temperature (Metric) Operating 5° to 45° C (ambient)
Relative Humidity Range 5 to 85 %, non-condensing
Dimensions (L x W x H) 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)
Weight (Metric) 0.9kg
Weight (English) 2 lb.
Model Orion Star A215 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter
Warranty 3 year meter warranty
Unit Size Each


Thermo Scientific Orion Star A200 320

Orion STAR A215 Advanced pH/Conductivity Benchtop Multiparameter Meter


Please Leave Your Product Enquiry Here. We will Get Back To You Soon.

Product Specifications

  • Product SKU : -
  • Weight (GRAM) : -
  • Dimension : -